Water Harvesting Stations

Engineered Water Reuse. Built for Reliable Performance

PPS Water Harvest Pump Stations provide a complete, factory-built solution for capturing, managing, and reusing valuable water resources. Each system is custom engineered to meet the specific hydraulic, storage, treatment, controls, and operating requirements of the application?integrating pumps, controls, filtration, treatment, and system components into one coordinated package.

Explore Our ProjectsGet Project Assistance

Engineered Around Your Water. Your Application. Your Requirements.

No two water harvesting applications are exactly alike. Available water sources, storage capacity, water quality, required flow and pressure, treatment requirements, and intended reuse can vary significantly from one project to the next. That?s why PPS custom water harvest pump stations are engineered around the specific requirements of each application.

PPS can integrate pumping, filtration, treatment, controls, storage interface, instrumentation, and monitoring into a coordinated factory-built system designed to work as one complete solution. Whether the application involves rainwater harvesting, reclaimed water, irrigation reuse, stormwater management, or dewatering, PPS brings decades of pumping-system expertise to the design.

The result is more than a collection of components?it?s a purpose-built water management system, engineered, assembled, and tested by PPS before it reaches the jobsite.

System Specifications

INDUSTRY

Water Harvest

APPLICATION

Booster, Flooded Suction, Submersible, Suction Lift, Vertical Turbine

PUMP TYPE

Centrifugal, Submersible Turbine, Vertical MultiStage Centrifugal

GPM - UP TO

500+

PSI - UP TO

150+

HP - UP TO

40

ELECTRICAL

208 Volt / 3 Phase
240 Volt / 1 Phase
240 Volt / 3 Phase
480 Volt / 3 Phase

VARIABLE FREQUENCY DRIVE

Standard

FILTRATION

Standard

Product Images

Water Harvest Station Features

Water Harvest Station Features

  • Automatic self-cleaning suction scanner filtration
  • Integrated filter controls eliminate the need for a secondary controller
  • 3-Way valve for supplemental water supply
  • Variable Frequency Drive
  • Remote control and monitoring available
  • Optional Ultraviolet water purifiers with UV monitors
  • Optional remote monitoring of tank level
  • Optional recirculation valve
  • Optional pH monitoring
  • Optional Chemical injection
  • Designed and built in the USA
  • 3 Year Warranty
  • 25-Year Rust-Through Warranty on all galvanized steel

Custom Enclosures and Prefabricated Buildings Available:

Additional Features and Options

Hydraulic Features

Butterfly Isolation Valves: Reduce station downtime by making it easy to quickly isolate pumps and other station components for service and maintenance.

Silent Check Valves: Prevent water from flowing backwards through the system, silently and with minimal pressure drop.

Air Relief Valves: Prevent entrained air from throttling system flow, continuously acting to release air from high points in the system.

High Pressure Relief Valves (Optional): Multiple surge and overpressure protection options are available to help protect the pumping system and downstream pipe network from damaging pressure events. Solutions may include high-pressure relief valves, surge anticipator valves, and PLC-integrated electrically operated valves selected to suit the application.

Monitoring & Control

UL Listed Control Panels

  • Engineered for Reliability: Custom control panels are designed and manufactured in a UL 508A listed facility using proven industrial components and established industry practices.
  • Safe, Serviceable & Supported: Comprehensive electrical and control documentation supports safe operation, troubleshooting, and maintenance. Non-proprietary industrial components provide long-term service flexibility, while PPS factory technical support remains available as an additional resource throughout the life of the system.

Application-Specific PLC Controls

  • Custom-Programmed for the Application: PLC programming is developed specifically around the operating requirements of each project and application, providing coordinated control of pumps, valves, instrumentation, and other system components.
  • Intelligent System Operation: Automated sequencing, equipment alternation, process control, alarming, and system protection help optimize performance while reducing operator involvement.
  • Flexible and Expandable: Control platforms can accommodate a wide range of instrumentation, equipment, communication protocols, and future expansion requirements.
  • Remote Monitoring Ready: Systems can be configured for integration with SCADA, telemetry, and other remote monitoring and control platforms.

Intuitive Touchscreen Operator Interface (HMI)

  • Designed for the Operator: The touchscreen interface is developed specifically for the application, presenting system information in a clear, logical, and easy-to-navigate format.
  • Simple System Management: Operators can quickly view operating status, process conditions, equipment performance, alarms, setpoints, and other key information from a centralized touchscreen interface.
  • Project-Specific Configuration: Screen layouts, controls, terminology, and displayed information can be customized to match the requirements of the project and end user.

Energy-Efficient Variable Frequency Drives

  • Demand-Based Pump Control: VFDs adjust pump operation to match changing demand, improving operating efficiency and reducing unnecessary energy consumption.
  • Consistent System Performance: Variable-speed operation provides smooth, precise control of pressure, flow, or other process requirements while reducing mechanical and electrical stress on pumping equipment.

System Diagnostics

  • Simplified Troubleshooting: Built-in diagnostic tools provide clear, actionable information to help operators quickly identify operating conditions, alarms, and equipment faults.
  • Improved Serviceability: Accessible operating data, alarm histories, and equipment status information help reduce troubleshooting time and support efficient maintenance and service.

Instrumentation & System Monitoring                                             

  • Stainless Steel Pressure Gauges: Provide local indication of suction and discharge pressures for system monitoring, commissioning, and troubleshooting.
  • Stainless Steel Pressure Transmitters: Provide continuous pressure feedback to the PLC through 4–20 mA analog signals, enabling precise VFD control, system monitoring, alarming, and pressure regulation.
  • Flow Measurement: Various flow measurement technologies are utilized based on application requirements to provide continuous system flow monitoring. Flow meters interface with the PLC for monitoring, totalization, alarming, reporting, and control functions.
  • Secondary System Protection: Independent safety devices provide an additional layer of system protection by initiating an alarm or system shutdown when abnormal operating conditions are detected.
Contact Us To Learn More

Call: (208)323-5300

or complete the contact form below to learn more:

  • This field is for validation purposes and should be left unchanged.

Engineering Specifications & CAD Drawings At Your Fingertips

Sign In / Register to Download Drawings and Specifications for our Standard Pumping Systems.

Most rainwater collection systems are comprised of the same basic components:

  • Catchment surface – rooftop or other raised solid surface. The best catchment systems have hard, smooth surfaces such as metal roofs or concrete areas. The amount of water harvested depends on the quantity of rainfall, the size of the surface, and the slope of the catchment area.
  • Gutters and downspouts – also known as distribution systems. They channel water from the catchment area to a holding container such as a barrel, cistern, or planted area.
  • Leaf screens – a screen that removes or catches debris.
  • Roof washers – a device that diverts the “first flush” of rain before it enters the storage tank. Most rainwater suppliers recommend that the “first flush” of water is diverted to an outside area of the storage system since the catchment surface may accumulate bird droppings, debris, and other pollution.
  • Storage tanks – In general, the storage tank is the most expensive component of a rainwater harvesting system. There are numerous types and styles of storage tanks available. Storage can be aboveground or underground. Storage containers can be made from galvanized steel, wood, concrete, clay, plastic, fiberglass, polyethylene, masonry, and more. Storage tank prices vary based on variables such as size, material, and complexity. To inhibit the growth of algae, storage tanks should be opaque and preferably placed away from direct sunlight. The tanks should also be placed close to the area of use and supply line to reduce the distance over which the water is delivered. Also, consider placing the storage on an elevated area to take advantage of gravity flow. The tank should always be placed on a stable and level area to prevent it from leaning and possibly collapsing.
  • Delivery systems – gravity-fed is the best system.? A water harvesting system can never be cross-connected with a potable water system. If a pump is used, it could contaminate the water in the water supplier’s main line in the street and then contaminate the water in the community. ?This is why it is vital to never set up a system that could be cross-connected with domestic water.